Shutter DC

The shutter DC module is used to control the 12-24VDC motor of blinds, rollers, shades, venetian blinds, windows, etc …

New functionality – support venetian blind slats tilting

Electrical diagrams 12 – 24VDC

Shutter DC
++VDC (12 – 24VDC)
-VDC (0V)
Q1Output for motor UP (open)
Q2Output for motor DOWN (close)
I2Input for switch/push button DOWN (close)
I1Input for switch/push button UP (open)
TSTerminal for digital temperature sensor (only for Shutter DC module compatible digital temperature sensor, which must be ordered separately).

Increased protection

Protection against accidental short circuit on outputs.

Protection agains wrong power supply connection.

Over temperature protection.

The most simplified installation

Extremely small size and special designed casing ensure the most simplified installation (ease of cabling fixing) inside a flush mounting box. Proved and tested by professional electricians.

1. Remove the switches from the box. Disconnect the wires from the switches.

2. Connect the wires to the NETIC module. Insert NETIC module in the box.

3. Fix the switches to the box.

-10 ° C

Extended operating temperatures from -10 to 40˚C.

Snowflake
Energy consumption

Reduce energy consumption & decrease your electricity costs and contribute to the greener environment

Extremely low own energy consumption, less than 0,4W.

Module is measuring the power consumption of the connected electrical motor in Watts and total consumption in kWh. The power consumption data can be easily collected and agregated without any additional costs.

Additional functionalities, make your home even more connected

The module can be used as an extension for control the heating/cooling system. The module has the option to connect a digital temperature sensor.

Packaging

Blister packaging is designed for retailers but at the same time it ensures lower cost of delivery.

Package contains: 1 module and 1 User manual

Setting parameters

Parameter no. 40 – Power reporting in Watts on power change for Q1 or Q2

Set value means percentage, set value from 0 – 100 = 0% – 100%. Available configuration parameters (data type is 1 Byte DEC):

  • default value 1
  • 0 – Reporting Disabled
  • 1 – 100 = 1% – 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

Note: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Parameter no. 42 – Power reporting in Watts by time interval for Q1 or Q2

Set value means time interval (0 – 32767) in seconds, when power report is send. Available configuration parameters (data type is 2 Byte DEC):

  • default value 300 (power report in Watts is send each 300s)
  • 0 – Reporting Disabled
  • 1 – 32767 = 1 second – 32767 seconds. Reporting enabled, power report is send with time interval set by entered value.

Parameter no. 71 – Operating modes

This parameter defines selection between two available operating modes. Configuration parameters (data type is 1 Byte DEC):

  • Default value 0
  • 0 – Shutter mode
  • 1 – Venetian mode (up/down and slate tilting)

Note: When setting parameter, module needs to be reconfigured! Please check detailed description in this manual.

Parameter no. 72 – Slats tilting full turn time

This parameter defines the time necessary for slats to make full turn (180 degrees). Configuration parameters (data type is 2 Byte DEC):

  • Default value 150 (1,5 seconds)
  • 0 – Tilting time disabled
  • 1 – 32767 = 0,01seconds – 327,67 seconds

Note: If time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining.

Parameter no. 73 – Slats position

This parameter defines slats position after up/down movement through UI or push buttons. Configuration parameters (data type is 1 Byte DEC):

  • 0 – Slats return to previously set position only in case of UI control.
  • 1 – Slats return to previously set position in case of UI control, momentary switch operation, or when the limit switch is reached.
  • 2 – Defoult – Slats return to previously set position in case of UI control, push button, when the limit switch is reached or after receiving a “STOP” control frame (Switch Multilevel Stop Level Change) from UI.

Parameter no. 74 – Motor moving up/down time

This parameter is used for motors without end positions, defines shutter motor moving time of complete opening or complete closing. Available configuration parameters (data type is 2 Byte DEC):

  • Default value 0
  • 0 – moving time disabled (working with limit switches)
  • 1 – 32767 = 0,1seconds – 3276,7seconds. After that time motor is stopped (relay goes to off state)

Note:

Important is that the reference position to manually set moving time is always shutter lower position!

Set parameter 74 to 0 and move the shutter (using up/down push buttons or main controller UI) to desired lower position. On this shutter position, set parameter 74 to time for complete opening or complete closing. At this point shutter can be moved up (open) for set time, but can’t be moved down because this position is already set as lower shutter position.

To change shutter lower position below already set (manual recalibration), parameter 74 must be set to 0 and repeat the procedure described above.

In case shutter has limit switches, but anyhow you would like to limit opening/closing position by time, you can still do it. In case you put time that is longer that opening/closing real time limited by limit switches, shutter will stop at limit switch, but the module relay will switch off after define time, not by shutter limit switch. Take in consideration that in this condition, the positioning with slider through UI will not show correct shutter position.

Parameter no. 76 – Motor operation detection

Power threshold to be interpreted when motor reach the limit switch. Available configuration parameters (data type is 1 Byte DEC):

  • Default value: 10 (10W).
  • Available settings: 0 – 127 (1-127 W)
  • The value 0 means reaching a limit switch will not be detected

Parameter no. 78 – Forced shutter calibration

By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode. Available configuration parameters (data type is 1 Byte DEC):

  • Default value: 0
  • 1 – Start calibration process (after shutter performs the calibration process, completing full cycle – up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0.

Parameter no. 85 – Power consumption max delay time

This parameter defines the max time before motor power consumption is read after one of the relays is switched ON. If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position,…) the relay will switch OFF. Time is defined by entering it manually. Available configuration parameters (data type is 1 Byte DEC):

  • Default value: 0 = time is set automatically
  • 3 – 50 = 0,3seconds – 5seconds (100ms resolution)

Parameter no. 86 – Power consumption at limit switch delay time

This parameter defines the max time at limit switch, when power consumption is below power threshold. If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit switch is reached. Available configuration parameters (data type is 1 Byte DEC):

  • Default value: 8
  • 3 – 50 = 0,3seconds – 5seconds (100ms resolution)

Parameter no. 90 – Relay delay time

This parameter defines the time delay between output relay switching (time between switching up/down and vice versa). Available configuration parameters (data type is 1 Byte DEC):

  • Default value: 5 = 500ms
  • 1 – 30 = 0,1seconds – 3seconds (100ms resolution)

Temperature sensor setting

Typography is the art and technique

Typography is the art and technique of arranging type to make written language legible, readable and appealing when displayed. The arrangement of type involves selecting typefaces, point size, line length, line-spacing (leading), letter-spacing (tracking), and adjusting the space within letters pairs (kerning).

Parameter no. 120 – Digital temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.

Available configuration parameters (data type is 1 Byte DEC):

  • Default value 5 (Temperature is reported on 0,5°C change)
  • 0 – Reporting disabled
  • 1- 127 = 0,1°C – 12,7°C, step is 0,1°C